Picosecond level timing resolution is a prerequisite capability for improved coincidence matching, time-of-flight measurements, and secondary vertex reconstruction. Here, we present the specification, design, and simulation results for a new Application Specific Integrated Circuit (ASIC), called PSEC6, in the TSMC...
Contents 1 Introduction 4 2 Material Properties, Gamma Absorption Cross-sections, and Electron Ranges 5 2.1 Materials and Material Properties . . . . . . . . . . . . . . . . . . . . ....
Gerber files are under pad-pickup-64-gerber folder. There are 64 minus 4 square pads on the front layer, four corner pads excluded. This is because only 60 channels are available. Each pads are labeled from 1 to 64, horizontal then vertical...
Anode Pad Sharing NIM Paper as Published: Nuclear Inst. and Methods in Physics Research, A 985 (2021) 164702; 22 Sept, 2020 \\~~~~~~~~~~~~~ Abstract: Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in...
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time resolutions of 30-50 psec for single photons. Incorporating a capacitively-coupled anode...